Explosion-proof junction box use Precautions for installation, use Note 1, the inside and outside of the box are equipped with grounding bolts, must be reliably grounded during installation.
2. The installation site must not exceed the provisions of this manual on the use of places.
3. The principle of “opening the lid after the power is turned off†should be observed on site.
4, according to the introduction of the outer diameter of the cable to select the appropriate size of the inner diameter of the sealing ring, the site should be used to tighten the compression nut, explosion-proof wiring box installation instructions to make the cable sealed, the interface should not be introduced cable plugging.
5. Users are not allowed to replace the parts of the product by themselves. They shall jointly solve the malfunctions occurring in the operation with the product manufacturers to prevent the occurrence of damage.
6. The installation, use and maintenance of the product shall comply with the product's instruction manual at the same time, IEC60079-14:2007 “Explosive Gas Environment Part 14: Design, Selection and Installation of Electrical Apparatusâ€, IEC60079-17:2007 “; Explosive Gas Environmental Technology parameter:
Implementation standards: GB3836.1-2000, GB3836.2-2000, GB3836.3-2000, IEC60079
Explosion-proof mark: ExdIIBT6, ExedIICT6
Explosion-proof grade: IIB grade anti-corrosion grade: WF1
Protection class: IP54
Contact Brand:UK Terminal Size & Size:According to customer's requirements Material:Engineering Plastic Size:360*360*120
2. The installation site must not exceed the provisions of this manual on the use of places.
3. The principle of “opening the lid after the power is turned off†should be observed on site.
4, according to the introduction of the outer diameter of the cable to select the appropriate size of the inner diameter of the sealing ring, the site should be used to tighten the compression nut, explosion-proof wiring box installation instructions to make the cable sealed, the interface should not be introduced cable plugging.
5. Users are not allowed to replace the parts of the product by themselves. They shall jointly solve the malfunctions occurring in the operation with the product manufacturers to prevent the occurrence of damage.
6. The installation, use and maintenance of the product shall comply with the product's instruction manual at the same time, IEC60079-14:2007 “Explosive Gas Environment Part 14: Design, Selection and Installation of Electrical Apparatusâ€, IEC60079-17:2007 “; Explosive Gas Environmental Technology parameter:
Implementation standards: GB3836.1-2000, GB3836.2-2000, GB3836.3-2000, IEC60079
Explosion-proof mark: ExdIIBT6, ExedIICT6
Explosion-proof grade: IIB grade anti-corrosion grade: WF1
Protection class: IP54
Contact Brand:UK Terminal Size & Size:According to customer's requirements Material:Engineering Plastic Size:360*360*120