First, the basic principles of lightning protection
The damage caused by thunder and other strong interference to the communication system and the resulting damage are serious and lightning protection will become necessary. Lightning consists of high-energy low-frequency components and highly permeable high-frequency components. There are two main forms, one is to directly conduct lightning damage equipment through metal pipelines or ground wires; the other is lightning impulse electromagnetic pulses of lightning passages and discharge passages, which sense the metal pipelines or ground lines by various coupling methods to generate waves. Damage to equipment. Most of the damage caused by this induction. For electronic information equipment, the hazard mainly comes from the lightning coupled electromagnetic pulse electromagnetic energy, through the following three channels generated by the transient surge. Metal pipelines, such as water pipes, power lines, antenna feeders, signal lines, aviation obstruction lamp leads and other surges; ground channel, ground power counterattack; space channel, electromagnetic group radiation energy.
Among them, the surge of the metal pipeline and the ground potential counterattack of the ground channel are the main causes of the damage of the electronic information system. Its most visible form of damage is damage caused on the power line. Therefore, it must be used as the focus of anti-expansion. As thunder and lightning penetrate the electronic information system, lightning protection will be a systematic project. The centerpiece of lightning protection is divergence and balance.
1. The bleed is to discharge the lightning and lightning electromagnetic pulse energy through the earth, and should comply with the principle of hierarchy, that is, to discharge excess energy into the ground as much as possible and as far as possible before introducing it into the communication system; the hierarchy is in accordance with the The established level of lightning protection discrimination weakens the energy of lightning. The lightning protection zone is also called electromagnetic compatibility zone. It divides the environment into several areas according to the intensity of feelings of lightning, lightning and electromagnetic pulses according to people, objects, and information systems. In the LPZOA area, all objects in the area may be directly struck by lightning. Therefore, all the special objects may lead away all the lightning currents, and the electromagnetic field in the area does not decay. In the LPZOB area, objects in the area could not be directly struck by lightning, but the electromagnetic field in the area did not decay. In LPZ1 area, objects in this area cannot be directly struck by lightning, and the current flowing to each conductor is further reduced than in LPZOB area. The electromagnetic field attenuation and effect depend on the overall shielding measures. Subsequent lightning protection zones (LPZ2 zone, etc.), if it is necessary to further reduce the guided current and electromagnetic field, shall be introduced into the subsequent lightning protection zone. The requirements for the protection zone shall be selected according to the environmental zone required by the system to be protected and the requirements for the lightning protection zone must be continued. condition. The higher the protection zone number, the lower the expected interference energy and interference voltage. In modern lightning protection technology, the installation of lightning protection zones is of great significance. It can guide us in the implementation of technical measures such as shielding, grounding, and other power connections.
2. Equilibrium is to keep the potential difference of each part of the system not enough to cause damage, that is, the potential of all the metal conductors in the system environment and the system itself remains substantially equal in the transient phenomenon, which is essentially based on equal voltage equipotential bonding. A potential compensation system consists of a reliable grounding system, metal wires for equipotential bonding, and equipotential bonding (lightning protection). This potential compensation system can be quickly protected in the presence of transients for a very short time. An equipotential is established between all conductive components in the area where the system is located. These conductive components also include active wires. Through this complete potential compensation system, an equipotential region can be formed in a very short time. This region may have a potential difference of tens of kilovolts with respect to the distant region. It is important that there is no significant potential difference between all conductive parts within the area where the system to be protected is located.
3. The lightning protection system consists of three parts, each part has its important role, there is no alternative. The external protection consists of a lightning arrester, a down conductor, and a grounding body. It can direct most of the lightning energy into the underground discharge. Transition protection, consisting of reasonable shielding, grounding, and routing, can reduce or block the induction introduced through each intrusion channel. Internal protection consists of voltage equalization and overvoltage protection to balance the system potential and limit the overvoltage amplitude.
Second, the role of lightning protection devices and technical parameters
Lightning arresters are also called equipotential connectors, overvoltage protectors, surge suppressors, surge absorbers, and lightning protection devices. Lightning protectors used for power line protection are called power surge protectors. In view of the current characteristics of lightning damage, lightning protection is especially in the lightning protection and rectification. The protection scheme based on lightning protection devices is the simplest and most economical lightning protection solution. The main function of the lightning protector is to maintain the same or limit the potential at both ends of the transient phenomenon and transfer the excess energy on the active conductor.
Into the underground discharge is an important part of achieving equal voltage equipotential bonding. Some of the main technical parameters of the lightning arrester: rated operating voltage, rated operating current, special batch and parallel power supply lightning protection device. Flow capacity, the ability of the lightning arrester to transfer lightning currents, in thousands of units, is related to the wave opening type. Lightning arresters can be divided into lightning protection devices that can prevent direct lightning strikes and lightning protection devices that can prevent inductive lightning. Lightning protectors that can prevent direct lightning strikes are generally used for line protection that may be hit by direct lightning strikes, such as the protection of the LPZOA area and the LPZ1 area. Use 10/35μs current waveform to test and indicate its current capacity. Anti-lightning surge arresters are generally used for line protection that cannot be hit by direct lightning strikes, such as the protection of the LPZOB zone at the junction with the LPX1 zone and the LPZ1 zone. The 8/20μs current waveform is used to test and indicate the current flow response time. The time required for the lightning arrester to control the transient phenomenon is related to the nature of the waveform. Residual pressure, surge arrester's ability to limit voltage transients, and lightning current amplitude and waveform properties.
Third, the selection of lightning protection device
For lightning protection based protection, to achieve the desired effect, attention should be paid to “arranging suitable lightning protection devices in a suitable placeâ€. The selection of lightning protection devices is very important.
1. The distribution of lightning currents between the various facilities entering the building is as follows: about 50% of the lightning current is discharged into the ground via external lightning protection devices, and another 50% of the lightning current will be distributed within the metal material of the entire system. . This evaluation model is used to estimate the current capacity of the SPDs and the metal wire specifications for equipotential bonding at the junction of LPAOA, LPZOB, and LPZ1 regions. The lightning current at this point is a 10/35μs current waveform. In the case of lightning current distribution among various metal substances: The lightning current amplitude of each part depends on the impedance and inductive reactance of each distribution channel. The distribution channel refers to metal materials that may be allocated to lightning currents, such as power lines, signal lines, Metal pipes and other groundings such as water pipes and metal structures can generally be roughly estimated only by their respective grounding resistance values. In the case of uncertainty, it can be assumed that the connections are equal in resistance, that is, the metal circuits distribute the current evenly.
2. When a power line is introduced overhead and the power line may be hit by a direct lightning strike, the lightning current entering the protected area within the building depends on the impedance and inductive reactance of the external route, the arrester discharge branch, and the user side route. If the impedance at both ends is the same, the power line is allocated to half of the direct lightning current. In this case, a lightning arrester with a lightning protection function must be used.
3. Subsequent assessment models are used to assess the distribution of lightning currents at the junction of the LPZ1 zone at the later time. Since the insulation impedance at the user side is much larger than the impedance of the discharge branch of the lightning arrester and the external lead line, the lightning current entering the subsequent lightning protection zone will be reduced, and no special estimation is needed in numerical value. It is generally required that the lightning protection device used in the subsequent lightning protection zone has a current flow capacity of 20 kA (8/20 μs) or less, and no lightning protection device with large flow capacity is required. The selection of surge arresters in the subsequent lightning protection zone should consider the energy distribution and voltage coordination between each level. When many factors are difficult to determine, it is a good choice to use series-parallel lightning protection devices. The serial-parallel type is a concept proposed based on the characteristics of many applications in modern lightning protection and the protection scope level distinction (as opposed to the traditional parallel lightning arrester). Its essence is the effective combination of multi-level discharger and filter technology with energy matching and voltage distribution. Serial-type lightning protection has the following features: Wide range of applications. Not only can it be applied routinely, but it is also suitable for sites that are difficult to distinguish in protected areas. Inducing the partial pressure and delay of the decoupling device under transient overvoltage to help achieve energy coordination. Reduce the rate of rise of transient interference to achieve low residual voltage and long life and extremely fast response time.
4. The choice of other parameters of the lightning protector depends on the level of the lightning protection zone where each object is protected. The operating voltage of the lightning protector is based on the rated voltage of all the components installed in the pilot circuit. Serial and lightning protectors also need to pay attention to their rated current.
5. Other factors that affect the distribution of the lightning current of the electronic wire: The decrease of the grounding resistance at the transformer terminal will increase the distribution current in the electronic wire. The increase in the length of the power supply cable will reduce the distribution current in the power line and allow a balanced current distribution in several wires. Short cable lengths and too low neutral impedance will cause current imbalance, causing differential mode interference. Multiple users connected to the power supply cable will reduce the effective impedance, resulting in an increase in the distribution current. In the connected state of the power supply, the temporary flow of the thunder mainly flows into the power line, which is why most of the lightning damage occurs at the power line.
Fourth, the installation of lightning protection device
1. Power line should be multi-level protection, multi-level protection is based on the level of each lightning protection zone, the gradual reduction of energy of lightning (energy distribution), so that the limits of voltage at each level with each other, and ultimately limit the value of over-voltage equipment insulation Within (voltage coordination).
In the following cases, multi-level protection becomes necessary: ​​one grade of lightning protection device fails or one of the lightning protection devices fails. The residual voltage of the lightning arrester does not match the insulation strength of the device, and the length of the cable in the building is long.
2. In most cases, the cable protection should be divided into at least two levels. The same level of lightning protection device may also include multiple levels of protection (such as serial and lightning protection devices). In order to achieve effective protection, lightning protection devices can be installed at the interfaces of lightning protection zones. The lightning protection devices can be used for a single electronic device or a space equipped with multiple electronic devices. All of the protection devices are usually shielded from space. The conductors of the minefield are connected with lightning arresters at the same time through the lightning protection zone interface. In addition, the protection scope of the SPD is limited. Generally, the protection effect will be degraded when the distance between the SPD and the equipment circuit exceeds 10m. This is because of the oscillation caused by reflection on the cable between the SPD and the device to be protected. Voltage, its magnitude is proportional to line length and load impedance.
3. In multi-stage protection using a powered child's lightning device, if attention is not paid to energy distribution, more lightning energy may be introduced into the protected area. This requires that the surge protector should be selected according to the aforementioned evaluation mode. Generally, the lightning arrester has the characteristics of higher lightning current and higher residual voltage. After the energy distribution, the lightning current flowing through the unshielded lightning arrester is extremely small, which is favorable for voltage limitation. Note that it is dangerous to select only low-response voltage surge arresters for final protection without considering voltage matching.
The key to achieving the energy distribution and voltage matching lies in the use of the intrinsic inductance of the cable between the two levels of surge arresters. The intrinsic inductance of the cable has a certain effect on the impediment of the buried current and the partial pressure, so that the lightning current is more distributed to the pre-stage discharge. It is generally required that the length of the cable between the two lightning arresters is about 15 meters, which is suitable for the situation where the protection ground wire and other cables are laid close to each other or in the same cable. The length of the branch line on the cable affects the required cable length. When the protection cable has a certain distance (>1m) from the cable to be protected, the cable length must be greater than 5m. In some cases where it is not suitable to use the cable itself as a decoupling measure, such as the two-level lightning protection zone near the interface or the cable length is short, special decoupling devices can be used, and there is no distance requirement.
4. Decoupling devices are important measures for energy distribution and voltage matching. The following materials can be used as decoupling devices: cables, inductors, and resistors.
Serial-type power supply lightning protector is a combination of lightning protection device that considers energy distribution and voltage matching and uses a filter as a decoupling device, and is suitable for applications in various occasions.
5. In some extreme cases, installing lightning arrestors will increase the possibility of equipment damage and must be eliminated; such situations occur. The lightning protector protects several lines, and the lightning arrester on one line fails or responds too slowly. This may cause common mode interference to be converted into differential mode interference and damage the device. This requires the implementation of multiple levels of protection and attention to the maintenance of lightning protection devices. Irrespective of the lightning protection zone, energy coordination and voltage distribution, the lightning protection device is installed casually. For example, only a lightning protection device is installed at the front of the device. Because there is no protection at the front stage, a strong lightning current will be attracted to the front of the device. The residual voltage of the surge protector exceeds the dielectric strength of the device. This requires that lightning protection devices must be installed in accordance with the principle of hierarchy.
6. In other cases, the wrong installation will prevent the device from being effectively protected. When the surge protector's connection line and the lightning arrester work too long, the voltage caused by the inductive reactance on the connection line will be extremely high, and the dangerous voltage will still be added to the device. This problem is even more serious in the application of the last stage surge arrester. obvious. The solution to this problem is to use short connection lines, but also to use two or more separate connection lines to share the magnetic field strength, reduce the pressure drop, single line thickening the connection line is no effect. If necessary, the length of the connecting wire can be reduced by changing the wiring of the protected wire so as to be close to the equipotential connection row (grounding point).
Lightning protector output line and input line, grounding line close, side by side laying. This situation has a serious impact on serial-type lightning arresters. When the output line (protected line), input line (unprotected line), and ground line of the series-type power supply surge protector are laid close to each other, a transient surge will be induced in the output line, although its strength is smaller than the original. But it can still be dangerous. The solution to this problem is to lay the input line, ground line, and output line separately or vertically, minimizing the length of parallel laying, and pulling away the distance of laying.
The grounding wire of the SPD is not connected to the protection ground of the protected equipment, that is, a separate lightning protection grounding is adopted. This will cause a dangerous voltage between the protected line and the equipment protection ground during transients. The solution to this problem is to connect the lightning protection device to the equipment protection ground.
The damage caused by thunder and other strong interference to the communication system and the resulting damage are serious and lightning protection will become necessary. Lightning consists of high-energy low-frequency components and highly permeable high-frequency components. There are two main forms, one is to directly conduct lightning damage equipment through metal pipelines or ground wires; the other is lightning impulse electromagnetic pulses of lightning passages and discharge passages, which sense the metal pipelines or ground lines by various coupling methods to generate waves. Damage to equipment. Most of the damage caused by this induction. For electronic information equipment, the hazard mainly comes from the lightning coupled electromagnetic pulse electromagnetic energy, through the following three channels generated by the transient surge. Metal pipelines, such as water pipes, power lines, antenna feeders, signal lines, aviation obstruction lamp leads and other surges; ground channel, ground power counterattack; space channel, electromagnetic group radiation energy.
Among them, the surge of the metal pipeline and the ground potential counterattack of the ground channel are the main causes of the damage of the electronic information system. Its most visible form of damage is damage caused on the power line. Therefore, it must be used as the focus of anti-expansion. As thunder and lightning penetrate the electronic information system, lightning protection will be a systematic project. The centerpiece of lightning protection is divergence and balance.
1. The bleed is to discharge the lightning and lightning electromagnetic pulse energy through the earth, and should comply with the principle of hierarchy, that is, to discharge excess energy into the ground as much as possible and as far as possible before introducing it into the communication system; the hierarchy is in accordance with the The established level of lightning protection discrimination weakens the energy of lightning. The lightning protection zone is also called electromagnetic compatibility zone. It divides the environment into several areas according to the intensity of feelings of lightning, lightning and electromagnetic pulses according to people, objects, and information systems. In the LPZOA area, all objects in the area may be directly struck by lightning. Therefore, all the special objects may lead away all the lightning currents, and the electromagnetic field in the area does not decay. In the LPZOB area, objects in the area could not be directly struck by lightning, but the electromagnetic field in the area did not decay. In LPZ1 area, objects in this area cannot be directly struck by lightning, and the current flowing to each conductor is further reduced than in LPZOB area. The electromagnetic field attenuation and effect depend on the overall shielding measures. Subsequent lightning protection zones (LPZ2 zone, etc.), if it is necessary to further reduce the guided current and electromagnetic field, shall be introduced into the subsequent lightning protection zone. The requirements for the protection zone shall be selected according to the environmental zone required by the system to be protected and the requirements for the lightning protection zone must be continued. condition. The higher the protection zone number, the lower the expected interference energy and interference voltage. In modern lightning protection technology, the installation of lightning protection zones is of great significance. It can guide us in the implementation of technical measures such as shielding, grounding, and other power connections.
2. Equilibrium is to keep the potential difference of each part of the system not enough to cause damage, that is, the potential of all the metal conductors in the system environment and the system itself remains substantially equal in the transient phenomenon, which is essentially based on equal voltage equipotential bonding. A potential compensation system consists of a reliable grounding system, metal wires for equipotential bonding, and equipotential bonding (lightning protection). This potential compensation system can be quickly protected in the presence of transients for a very short time. An equipotential is established between all conductive components in the area where the system is located. These conductive components also include active wires. Through this complete potential compensation system, an equipotential region can be formed in a very short time. This region may have a potential difference of tens of kilovolts with respect to the distant region. It is important that there is no significant potential difference between all conductive parts within the area where the system to be protected is located.
3. The lightning protection system consists of three parts, each part has its important role, there is no alternative. The external protection consists of a lightning arrester, a down conductor, and a grounding body. It can direct most of the lightning energy into the underground discharge. Transition protection, consisting of reasonable shielding, grounding, and routing, can reduce or block the induction introduced through each intrusion channel. Internal protection consists of voltage equalization and overvoltage protection to balance the system potential and limit the overvoltage amplitude.
Second, the role of lightning protection devices and technical parameters
Lightning arresters are also called equipotential connectors, overvoltage protectors, surge suppressors, surge absorbers, and lightning protection devices. Lightning protectors used for power line protection are called power surge protectors. In view of the current characteristics of lightning damage, lightning protection is especially in the lightning protection and rectification. The protection scheme based on lightning protection devices is the simplest and most economical lightning protection solution. The main function of the lightning protector is to maintain the same or limit the potential at both ends of the transient phenomenon and transfer the excess energy on the active conductor.
Into the underground discharge is an important part of achieving equal voltage equipotential bonding. Some of the main technical parameters of the lightning arrester: rated operating voltage, rated operating current, special batch and parallel power supply lightning protection device. Flow capacity, the ability of the lightning arrester to transfer lightning currents, in thousands of units, is related to the wave opening type. Lightning arresters can be divided into lightning protection devices that can prevent direct lightning strikes and lightning protection devices that can prevent inductive lightning. Lightning protectors that can prevent direct lightning strikes are generally used for line protection that may be hit by direct lightning strikes, such as the protection of the LPZOA area and the LPZ1 area. Use 10/35μs current waveform to test and indicate its current capacity. Anti-lightning surge arresters are generally used for line protection that cannot be hit by direct lightning strikes, such as the protection of the LPZOB zone at the junction with the LPX1 zone and the LPZ1 zone. The 8/20μs current waveform is used to test and indicate the current flow response time. The time required for the lightning arrester to control the transient phenomenon is related to the nature of the waveform. Residual pressure, surge arrester's ability to limit voltage transients, and lightning current amplitude and waveform properties.
Third, the selection of lightning protection device
For lightning protection based protection, to achieve the desired effect, attention should be paid to “arranging suitable lightning protection devices in a suitable placeâ€. The selection of lightning protection devices is very important.
1. The distribution of lightning currents between the various facilities entering the building is as follows: about 50% of the lightning current is discharged into the ground via external lightning protection devices, and another 50% of the lightning current will be distributed within the metal material of the entire system. . This evaluation model is used to estimate the current capacity of the SPDs and the metal wire specifications for equipotential bonding at the junction of LPAOA, LPZOB, and LPZ1 regions. The lightning current at this point is a 10/35μs current waveform. In the case of lightning current distribution among various metal substances: The lightning current amplitude of each part depends on the impedance and inductive reactance of each distribution channel. The distribution channel refers to metal materials that may be allocated to lightning currents, such as power lines, signal lines, Metal pipes and other groundings such as water pipes and metal structures can generally be roughly estimated only by their respective grounding resistance values. In the case of uncertainty, it can be assumed that the connections are equal in resistance, that is, the metal circuits distribute the current evenly.
2. When a power line is introduced overhead and the power line may be hit by a direct lightning strike, the lightning current entering the protected area within the building depends on the impedance and inductive reactance of the external route, the arrester discharge branch, and the user side route. If the impedance at both ends is the same, the power line is allocated to half of the direct lightning current. In this case, a lightning arrester with a lightning protection function must be used.
3. Subsequent assessment models are used to assess the distribution of lightning currents at the junction of the LPZ1 zone at the later time. Since the insulation impedance at the user side is much larger than the impedance of the discharge branch of the lightning arrester and the external lead line, the lightning current entering the subsequent lightning protection zone will be reduced, and no special estimation is needed in numerical value. It is generally required that the lightning protection device used in the subsequent lightning protection zone has a current flow capacity of 20 kA (8/20 μs) or less, and no lightning protection device with large flow capacity is required. The selection of surge arresters in the subsequent lightning protection zone should consider the energy distribution and voltage coordination between each level. When many factors are difficult to determine, it is a good choice to use series-parallel lightning protection devices. The serial-parallel type is a concept proposed based on the characteristics of many applications in modern lightning protection and the protection scope level distinction (as opposed to the traditional parallel lightning arrester). Its essence is the effective combination of multi-level discharger and filter technology with energy matching and voltage distribution. Serial-type lightning protection has the following features: Wide range of applications. Not only can it be applied routinely, but it is also suitable for sites that are difficult to distinguish in protected areas. Inducing the partial pressure and delay of the decoupling device under transient overvoltage to help achieve energy coordination. Reduce the rate of rise of transient interference to achieve low residual voltage and long life and extremely fast response time.
4. The choice of other parameters of the lightning protector depends on the level of the lightning protection zone where each object is protected. The operating voltage of the lightning protector is based on the rated voltage of all the components installed in the pilot circuit. Serial and lightning protectors also need to pay attention to their rated current.
5. Other factors that affect the distribution of the lightning current of the electronic wire: The decrease of the grounding resistance at the transformer terminal will increase the distribution current in the electronic wire. The increase in the length of the power supply cable will reduce the distribution current in the power line and allow a balanced current distribution in several wires. Short cable lengths and too low neutral impedance will cause current imbalance, causing differential mode interference. Multiple users connected to the power supply cable will reduce the effective impedance, resulting in an increase in the distribution current. In the connected state of the power supply, the temporary flow of the thunder mainly flows into the power line, which is why most of the lightning damage occurs at the power line.
Fourth, the installation of lightning protection device
1. Power line should be multi-level protection, multi-level protection is based on the level of each lightning protection zone, the gradual reduction of energy of lightning (energy distribution), so that the limits of voltage at each level with each other, and ultimately limit the value of over-voltage equipment insulation Within (voltage coordination).
In the following cases, multi-level protection becomes necessary: ​​one grade of lightning protection device fails or one of the lightning protection devices fails. The residual voltage of the lightning arrester does not match the insulation strength of the device, and the length of the cable in the building is long.
2. In most cases, the cable protection should be divided into at least two levels. The same level of lightning protection device may also include multiple levels of protection (such as serial and lightning protection devices). In order to achieve effective protection, lightning protection devices can be installed at the interfaces of lightning protection zones. The lightning protection devices can be used for a single electronic device or a space equipped with multiple electronic devices. All of the protection devices are usually shielded from space. The conductors of the minefield are connected with lightning arresters at the same time through the lightning protection zone interface. In addition, the protection scope of the SPD is limited. Generally, the protection effect will be degraded when the distance between the SPD and the equipment circuit exceeds 10m. This is because of the oscillation caused by reflection on the cable between the SPD and the device to be protected. Voltage, its magnitude is proportional to line length and load impedance.
3. In multi-stage protection using a powered child's lightning device, if attention is not paid to energy distribution, more lightning energy may be introduced into the protected area. This requires that the surge protector should be selected according to the aforementioned evaluation mode. Generally, the lightning arrester has the characteristics of higher lightning current and higher residual voltage. After the energy distribution, the lightning current flowing through the unshielded lightning arrester is extremely small, which is favorable for voltage limitation. Note that it is dangerous to select only low-response voltage surge arresters for final protection without considering voltage matching.
The key to achieving the energy distribution and voltage matching lies in the use of the intrinsic inductance of the cable between the two levels of surge arresters. The intrinsic inductance of the cable has a certain effect on the impediment of the buried current and the partial pressure, so that the lightning current is more distributed to the pre-stage discharge. It is generally required that the length of the cable between the two lightning arresters is about 15 meters, which is suitable for the situation where the protection ground wire and other cables are laid close to each other or in the same cable. The length of the branch line on the cable affects the required cable length. When the protection cable has a certain distance (>1m) from the cable to be protected, the cable length must be greater than 5m. In some cases where it is not suitable to use the cable itself as a decoupling measure, such as the two-level lightning protection zone near the interface or the cable length is short, special decoupling devices can be used, and there is no distance requirement.
4. Decoupling devices are important measures for energy distribution and voltage matching. The following materials can be used as decoupling devices: cables, inductors, and resistors.
Serial-type power supply lightning protector is a combination of lightning protection device that considers energy distribution and voltage matching and uses a filter as a decoupling device, and is suitable for applications in various occasions.
5. In some extreme cases, installing lightning arrestors will increase the possibility of equipment damage and must be eliminated; such situations occur. The lightning protector protects several lines, and the lightning arrester on one line fails or responds too slowly. This may cause common mode interference to be converted into differential mode interference and damage the device. This requires the implementation of multiple levels of protection and attention to the maintenance of lightning protection devices. Irrespective of the lightning protection zone, energy coordination and voltage distribution, the lightning protection device is installed casually. For example, only a lightning protection device is installed at the front of the device. Because there is no protection at the front stage, a strong lightning current will be attracted to the front of the device. The residual voltage of the surge protector exceeds the dielectric strength of the device. This requires that lightning protection devices must be installed in accordance with the principle of hierarchy.
6. In other cases, the wrong installation will prevent the device from being effectively protected. When the surge protector's connection line and the lightning arrester work too long, the voltage caused by the inductive reactance on the connection line will be extremely high, and the dangerous voltage will still be added to the device. This problem is even more serious in the application of the last stage surge arrester. obvious. The solution to this problem is to use short connection lines, but also to use two or more separate connection lines to share the magnetic field strength, reduce the pressure drop, single line thickening the connection line is no effect. If necessary, the length of the connecting wire can be reduced by changing the wiring of the protected wire so as to be close to the equipotential connection row (grounding point).
Lightning protector output line and input line, grounding line close, side by side laying. This situation has a serious impact on serial-type lightning arresters. When the output line (protected line), input line (unprotected line), and ground line of the series-type power supply surge protector are laid close to each other, a transient surge will be induced in the output line, although its strength is smaller than the original. But it can still be dangerous. The solution to this problem is to lay the input line, ground line, and output line separately or vertically, minimizing the length of parallel laying, and pulling away the distance of laying.
The grounding wire of the SPD is not connected to the protection ground of the protected equipment, that is, a separate lightning protection grounding is adopted. This will cause a dangerous voltage between the protected line and the equipment protection ground during transients. The solution to this problem is to connect the lightning protection device to the equipment protection ground.
Organic Fertilizer is different from traditional fertilizer. Ihe source of organic fertilizer is from plant, animal, or mineral that is applied to plant without any processing. It plays an important role in the sustaining development of agriculture. Organic fertilizer . It can add organic matters to soil; Adjust soil PH and improve soil fertility; Increase plant resistance and increase plant yield; Raise the plant nutritional level for good-quality fruit.