Misunderstanding 1: moisture protection = waterproof
In many people's ideas, moisture protection and waterproofing can be painted equal. In fact, this concept is also inaccurate. Moisture-proof is mixed with a moisture-proof agent in the plate substrate, and the moisture-proof agent is colorless. In order to make it different from ordinary plates, manufacturers add green or red (mostly green, more advanced red) as identification marks in the plate. The moisture-proof agent does not have any effect on the waterproof property of the panel itself. Practice has proved that the board with moisture-proof agent and the board without moisture-proof agent are immersed in water and the expansion rate is the same. The so-called moisture-proofing is only effective for the moisture in the air.
Misunderstanding 2 : It smells like formaldehyde
The European standard in this respect is 9 milligrams per 100 grams. China's regulations concerning formaldehyde in man-made panels: Man-made boards (medium density fiberboard, high density fiberboard, chipboard, oriented strand board, etc.) Per 100 grams of free formaldehyde is allowed to contain less than 9 milligrams. When you buy cabinets, the amount of formaldehyde released is an indicator that must not be ignored.
Misunderstanding 3: inferior plate
Quality depends on the material. The reason why the cabinets produced by small factories are cheap is that except for processing methods, the most important ones are the plates and the costs. The surface of the poor quality board has a bottom, color difference, and feels uneven. The surface of the tri-aminoamine veneer is brittle. After being subjected to external force, it easily falls off. From the cross section, the fiber particles of the wood chips are uneven in thickness, the gap is large, and even mud and nails are left. And other rubbish such as stones.
How to check if the exterior is firm and tight?
First, look carefully. Good cabinet installation must first strictly follow the requirements of the drawings and must not change position; secondly, the external appearance of the cabinet should be kept in the original state with no scars; then the cabinets and cabinets should be kept horizontal; the door panel and the drawer surface should be divided up and down, front and back, and left and right. Also be consistent.
Second, the data should be clear. The allowable error degree of cabinet installation should be less than or equal to 2mm; the distance between the left and right sides of the cabinet body and the wall surface is less than or equal to 10mm; the stove cabinet installation should be aligned with the range hood, the allowable tolerance is ±20mm; the door and the cabinet body, the door and the The relative position difference between adjacent surfaces of the door, drawers and cabinets, drawers and doors, drawers and drawers shall be less than or equal to 2mm; cabinet cabinets shall be used to fasten adjacent cabinets, cabinets and cabinets. The misalignment and surface misalignment tolerance between the cabinet and the cabinet is less than or equal to 1mm. You can use a small amount of measurement can be, very simple.
Third, look at the degree of firmness. Firstly, the wall cabinet and the wall should be firmly connected, and the connecting screw ≥M8. Each 900mm length must be connected with two or more fixing points to ensure that the load-bearing requirements are met; the connection between the mounting parts of the next spliced ​​structure cabinet should be firm and secure, and the fastening screw must not be loosened. All should be tightened; there should be a level hood installation, which should be firmly fixed to the wall or the connecting plate, and should not be loosened or shaken. There must also be a firm connection between the table top and the cabinet, and must not be loosened.
Fourth, look at the safety performance. Safety is very important. Therefore, all drawers and baskets should be easy to pull, no block, and limited protection devices to prevent direct extraction; there are all exposed sharp corners of the cabinet must be dulled, metal parts in the touchable position to be sanded, No burrs and sharp corners are allowed.
Fifth, look at cleanliness. The formal installation site should pay attention to civilized construction. Before the construction, clean the site and remove the debris. During the construction, we must also pay attention to the protection of the product and the site. Clean up the garbage in time, and must not allow the sawdust and smoke to fly. We must not open the customer's range hood to extract the smoke. After the final installation, you must Clean up the sawdust and dust in the cabinet, then clean the cabinet body and table top, and finally clean the site, collect the packaging and the garbage left after the construction, and take it away.