Note the following when installing an electromagnetic pulse valve:
1. The best installation method of the solenoid valve is perpendicular to the horizontal pipe and the coil is upward. Allow ±30° tilt when conditions do not allow. Otherwise, normal use is not guaranteed.
2. The parameters on the nameplate of the solenoid valve should be consistent with the actual use requirements.
3. The arrow on the valve body of the solenoid valve should be consistent with the flow direction of the medium.
4. In order to ensure the normal use of the solenoid valve, please install a water separator in front of the solenoid valve.
5. In the hazardous environment, in order to prevent accidents such as explosions caused by electric sparks, explosion-proof solenoid valves should be used.
6. Please thoroughly purge the air bag and pipeline before installation to avoid the malfunction of the solenoid valve caused by foreign matter damage to the diaphragm.
7. When the solenoid valve fails, it is recommended to install a bypass (bypass) device for timely isolation and easy maintenance.
8. When the solenoid valve is not installed temporarily, it can be stored in 0~40°C, relative humidity ≤80%, but indoors without corrosive gas, avoid open storage as much as possible.
9. After opening the box, check the instruction manual, the factory certificate and the packing list. Then check the product name and model according to the list, and check whether the nameplate matches the order form. If it is missing or does not match, you should contact the manufacturer in time to try to solve it.