1.Applications of chlorinated paraffinÂ
 It is used as flame retardant for impregnating textiles & fabric of all kinds. Find applications
 in paint industries for the manufacturing of fireproof paints. They have also found application
 in adhesives, sealants, and caulks and are used in the automotive and metalworking industriesÂ
as lubricants for wide range of machining and engineering operations.Â
2.Specification of chlorinated paraffin
Check Item |
Check Conclusion |
Color(PT-CO), Mark |
100 |
Chlorine Content,wt pc |
51.5 |
Density(50deg.c),g/cm3 |
1.24 |
Viscosity50deg.c,mPa.s |
170 |
Refractive index n20D |
1.51 |
Heat loss130deg.c,2hrs% |
0.3 |
Heat stability175deg.c,4hrs,chlorine gas 10L/h, HCL%≤ |
0.10 |
Â
1.Applications of chlorinated paraffinÂ
 It is used as flame retardant for impregnating textiles & fabric of all kinds. Find applications
 in paint industries for the manufacturing of fireproof paints. They have also found application
 in adhesives, sealants, and caulks and are used in the automotive and metalworking industriesÂ
as lubricants for wide range of machining and engineering operations.Â
2.Specification of chlorinated paraffin
Check Item |
Check Conclusion |
Color(PT-CO), Mark |
100 |
Chlorine Content,wt pc |
51.5 |
Density(50deg.c),g/cm3 |
1.24 |
Viscosity50deg.c,mPa.s |
170 |
Refractive index n20D |
1.51 |
Heat loss130deg.c,2hrs% |
0.3 |
Heat stability175deg.c,4hrs,chlorine gas 10L/h, HCL%≤ |
0.10 |
Â
Chemical Industry Mass Flow Meter
Sealand is a professional supplier of Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter, ATEX, IECEx & CE approved.
The meter can work with a pulse receiver(Count). The connection is as follows. The resistance value is up to the cable length & the max. input pulse frequency of receiver. Current 10mA is suitable for most receivers; however, you can reduce the resistance value when the cable is long. The max. current could be 50mA. Please use the fixed frequency output function to check if the cable length & resistance value is suitable.
Please check following items before operation, and operate according to relevant rules.
a) If the meter is damaged during shipment and installation;
b) If the voltage is same as marked on nameplate;
c) If the fuse is correct;
d) If the meter is grounded properly.
e) If the Meter SN on the nameplate of sensor and transmitter are the same.
If everything is fine, please open all valves, make the pipeline full of liquid and then power on
the meter for warm-up for 20min before operation. Finally, conduct zero calibration after first
start, and shall do it again if the meter is moved to another site.
Preparation for zero calibration:
a) Power on the meter for approximately 20min for warm-up;
b) Run the process fluid through the sensor until the sensor temperature reaches the normal
process operating temperature.
c) Close the shutoff valve downstream from the sensor.
d) Ensure that the sensor is filled with fluid and the process flow has completely stopped.
Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter
Zhejiang Sealand Technology Co., Ltd. , https://www.sealandflowmeters.com